马 睿1,刘淑莲2,郑水英1.轴承支座对轴流风机性能试验的影响[J].轻工机械,2016,34(4): |
轴承支座对轴流风机性能试验的影响 |
CFD numerical simulation combined with theoretical analysis were used to research and discuss the obstructingeffect, caused by the bearing support of type-C device, on the outlet airflow in axial-flow fan performance test. Thethree-dimensional flow field in test device was simulated through FLUENT. The relations between total pressureefficiency and flow rate were studied when the distance between bearing support and fan outlet was different, and thestructural strength and stiffness were also analyzed through ANSYS. The results indicated that test results weresignificantly affected when bearing support was too close to fan outlet, so particular consideration should be taken intothe design of fan performance test device. |
|
DOI:10.3969/j.issn.1005 -2895.2016.04.018 |
中文关键词: 轴流通风机 性能试验 C型管道进口 数值模拟 |
英文关键词: |
基金项目: |
|
摘要点击次数: 1495 |
全文下载次数: 1278 |
中文摘要: |
为了研究风机性能试验中支承结构与风机出口的距离对性能试验的影响,采用理论分析和CFD数值模拟相结
合的方法进行研究。分析轴流风机性能试验中C型装置的轴承支座对出口气流的阻碍作用。利用FLUENT软件对试验
装置的三维流场进行数值模拟,计算了轴承支座与风机出口的距离不同时,全压效率与流量间的关系,并用ANSYS对结
构进行了强度和刚度分析。结果表明轴承支座距离风机出口过近时会显著影响试验结果,应在风机性能试验台的设计
过程中加以注意。 |
英文摘要: |
axial-flow fan; performance test; type C ducted inlet; numerical simulation |