袁朝阳, 陶乐仁, 虞中旸.基于力控的空气源热泵热水器系统非稳定性研究[J].轻工机械,2017,35(3):14-19
基于力控的空气源热泵热水器系统非稳定性研究
Unstability Study of Air Source Heat Pump Water Heater Based on Force Control
  
DOI:10.3969/j.issn.1005 2895.2017.03.004
中文关键词:  空气源热泵热水器  力控组态软件  能效比  瞬时能效比
英文关键词:air source heat pump water heater  force control configuration software  COP(coefficient of performance)  instantaneous energy efficiency ratio
基金项目:
作者单位
袁朝阳, 陶乐仁, 虞中旸 上海理工大学 能源与动力学院 上海 200093 
摘要点击次数: 1872
全文下载次数: 1149
中文摘要:
      针对空气源热泵热水器运行工况随着加热水温的变化而变化,系统稳定性较难确定,在整个运行过程中存在能效比CCOP变化区间较大的问题。采用力控组态软件为数据采集系统,设计并搭建了一套空气源热泵热水器试验台。通过研究系统在变工况下运行时各个参数的变化趋势,分析影响系统稳定性的因素以期改进优化。试验结果表明:在初始条件不变的情况下,随着加热水温的上升,系统的瞬时能效比CCOPins不断减小,在加热后期过热度接近0 ℃时减小幅度加剧。整个运行过程过热度都在不断减小,0 ℃时压缩机进入吸气带液状态,吸气带液一定程度上改善了压缩机的工作性能,但长时间的吸气带液使蒸发器侧换热一直不充分,反而使系统的运行性能进一步恶化。通过研究系统整个非稳定运行中的变化过程,表明过热度是影响系统效率的主要因素。
英文摘要:
      Aiming at operating condition of the air source heat pump water heater changing with the change of heating water temperature, poor system stability and the variation range of coefficient of performance too large during the operation. Adopted force control configuration software as the data acquisition system to design and build the air source heat pump water heater test rig. By studying the change trend of each parameter when the system was running under variable operating conditions, analyzed the influence factors of system stability to improve optimization of system performance. The test results show that, under the condition of the same initial condition, the instantaneous energy efficiency ratio of the system decreases with the increase of the circulating hot water temperature. The rate of decrease of instantaneous energy efficiency ratio increases when the degree of superheat is close to 0 ℃ in the latter stage of heating. The degree of superheat decreases during the operation. The compressor enters the gas liquid two phase region when the degree of superheat is 0 ℃. It can improve the working performance of the compressor in a certain extent, but heat transfer of the evaporator side is not inadequate when the gas liquid two phase area last for a long time. The running performance of the system is further deteriorated. Superheat is the main factor affecting the efficiency of system from the study of whole instability process.